Sale!

IS200TBCIH1BBC GE

  • Dual-Channel Redundancy: A Middle Eastern power plant achieved 99.99% uptime during module swaps, avoiding $1.8M/year in lost generation.
  • High Precision: 16-bit resolution reduces RTD measurement errors by 60% vs. 12-bit modules, critical for optimizing gas turbine fuel-air ratios.
  • Rugged Design: IP65-rated enclosure with conformal coating withstands salt spray (ISO 9227) and 5 g vibrations (IEC 60068-2-6), proven in 10+ years of offshore deployments.
  • Hot-Swap Capability: 70% faster maintenance than legacy modules (GE case study: 15-minute vs. 50-minute replacement).
Manufacturer:
Part number: IS200TBCIH1BBC
Our extensive catalogue, including : IS200TBCIH1BBC , is available now for dispatch to the worldwide.
  • Full 12-month warranty
  • Available for dispatch immediately
  • We deliver worldwide

Description

GE Fanuc IS200TBCIH1BBC Mark VIe™ Thermocouple/RTD Input Module

 

The GE Fanuc IS200TBCIH1BBC is a high-precision analog input module designed for GE’s Mark VIe™ gas turbine control system, specializing in thermocouple (TC) and resistance temperature detector (RTD) measurements. Engineered for power generation, oil & gas, and industrial process control, this module supports 8 isolated channels with 16-bit resolution, enabling real-time temperature monitoring in extreme environments (-40°C to 85°C). The IS200TBCIH1BBC features dual-channel redundancy, EMI shielding, and hot-swap capability, reducing unplanned downtime by 45% in critical applications like gas turbines and boilers.

1. Product Description

The IS200TBCIH1BBC serves as the primary interface for temperature sensing in GE’s Mark VIe system, connecting to thermocouples (J/K/T/R/S types) and RTDs (Pt100/Pt500). Its rugged design includes conformal coating for moisture resistance and triple-layer EMI shielding, ensuring stable performance in high-vibration settings (e.g., offshore platforms, steel mills). With auto-ranging inputs and self-diagnostic LEDs, the module simplifies commissioning and maintenance, while dual-channel redundancy (N+1) eliminates single points of failure. Key applications include gas turbine inlet temperature control, boiler efficiency optimization, and industrial furnace monitoring.

2. Product Parameters

Parameter Value
Channels 8 isolated TC/RTD inputs (configurable per channel)
Input Types TC: J/K/T/R/S (±20 mV); RTD: Pt100/500 (2/3/4-wire)
Resolution 16-bit (0.1°C for RTDs, 0.5°C for TCs)
Accuracy ±0.15% (RTD); ±2°C (TC, type K)
Redundancy Dual-channel auto-failover (<50 ms switchover)
Power Supply 24 VDC ±15% (rack-powered)
Temperature Range -40°C to 85°C (operational); -55°C to 100°C (storage)
Compatibility GE Mark VIe racks, IS200TBCIH1A (non-redundant), IS200TBCIH2C (16-channel)
IS200TBCIH1BBC

IS200TBCIH1BBC

3. Advantages and Features

  • Dual-Channel Redundancy: A Middle Eastern power plant achieved 99.99% uptime during module swaps, avoiding $1.8M/year in lost generation.
  • High Precision: 16-bit resolution reduces RTD measurement errors by 60% vs. 12-bit modules, critical for optimizing gas turbine fuel-air ratios.
  • Rugged Design: IP65-rated enclosure with conformal coating withstands salt spray (ISO 9227) and 5 g vibrations (IEC 60068-2-6), proven in 10+ years of offshore deployments.
  • Hot-Swap Capability: 70% faster maintenance than legacy modules (GE case study: 15-minute vs. 50-minute replacement).

4. Application Areas and Use Cases

Industry-Specific Applications:
  • Power Generation: Monitoring gas turbine inlet temperatures (1,200°C max) for efficiency optimization.
  • Oil & Gas: Measuring subsea pipeline compressor temperatures to prevent icing (BP 案例:提前 3 days 预警,避免 $2.5M repair).
  • Metallurgy: Controlling annealing furnace temperatures in steel production (某宝钢案例:温度波动≤1°C,良品率提升 4%).
Case Study:
A German biomass power plant deployed IS200TBCIH1BBC to monitor 32 boiler zones. The module’s RTD precision reduced fuel consumption by 6%, saving €400,000 annually while extending boiler 寿命 by 2 years.

5. Competitor Comparison

Feature IS200TBCIH1BBC Comparable Modules
Redundancy Switchover Time <50 ms 80–120 ms
TC Types Supported 5 (J/K/T/R/S) 3–4
RTD Wire Support 4-wire (factory-calibrated) 2/3-wire (field-calibration required)
MTBF 180,000 hours 120,000 hours
IS200TBCIH1BBC

IS200TBCIH1BBC

6. Selection Recommendations

  1. Sensor Type:
    • Choose IS200TBCIH1BBC for mixed TC/RTD setups; use IS200TBCIH1A for TC-only (25% cost savings).
    • 4-wire RTDs recommended for <0.1°C accuracy (e.g., turbine inlet sensors).
  2. Redundancy Needs:
    • Dual modules (N+1) for gas turbines and offshore assets (cost +35%, failure risk ↓80%).
    • Single modules for non-critical processes (e.g., HVAC, water pumps).
  3. Environmental Factors:
    • IS200TBCIH1BBCH variant for -55°C to 125°C (Arctic LNG plants).
    • Ensure 5 cm airflow in enclosures >50°C to maintain accuracy.

7. Precautions

  • Installation: Use shielded twisted-pair cables (Belden 9841) and torque terminals to 0.5 N·m.
  • Calibration: Factory offsets valid for 5 years; recheck annually in high-temperature zones (>600°C).
  • Safety: Power down before hot-swapping; follow NEC 501 for hazardous locations (Class I, Div 2).

 

Shanxi Xinyeda International Trade Co., Ltd. is your trusted partner for GE Fanuc IS200TBCIH1BBC and Mark VIe spare parts. Visit www.xydcontrol.com or contact us for customized solutions and 24/7 technical support.
We've got you covered
We give you access to a global supply of automation parts at your fingertips, ensuring that manufacturers around the world can avoid unnecessary downtime and continue to do what they do best – making our world possible.
  • Full 12-month warranty on all components
  • Dedicated after-sales support
  • Same-day dispatch on 1000s of parts
  • All units are fully tested
Continue Searching
We're here when you need us
What happens next?
  • 1. Email confirmation
    You will get an email confirming that we have received your enquiry.
  • 2. Dedicated Account Manager
    One of our team will be in touch to confirm your part(s) specification and condition.
  • 3. Your quote
    You will receive a comprehensive quote tailored to your specific needs.