Description
Parameter Name |
Parameter Value |
Product Model |
IBA 940143201 |
Manufacturer |
ABB |
Product Category |
Industrial Battery (Backup Power Supply) |
Application |
Emergency Power Systems, UPS, Control Panels, Industrial Automation |
Battery Type |
Sealed Lead-Acid (SLA) |
Nominal Voltage |
12 V DC |
Nominal Capacity |
7 Ah (20-hour rate) |
Dimensions (L×W×H) |
151 mm × 65 mm × 94 mm |
Terminal Type |
M6 threaded terminals |
Operating Temperature |
-20°C to +50°C |
Shelf Life |
Up to 3 years (unloaded, at 25°C) |
Certification |
IEC 62133, CE, RoHS |
Mounting Method |
Vertical or horizontal (non-spill design) |
The ABB IBA 940143201 is a rugged sealed lead-acid (SLA) industrial battery designed to provide reliable backup power in critical automation and control systems. Engineered for durability and long-lasting performance, this 12 V, 7 Ah battery serves as a vital component in uninterruptible power supplies (UPS), emergency lighting systems, and industrial control panels, ensuring seamless operation during power outages or transient faults. As part of ABB’s Power Management portfolio, the IBA 940143201 combines maintenance-free design with high energy density, making it ideal for applications where downtime is costly, such as manufacturing plants, data centers, and healthcare facilities.
The IBA 940143201 features a hermetically sealed construction that prevents acid leakage, allowing safe installation in any orientation (vertical or horizontal) without the risk of spills. Its deep-cycle capability enables repeated charging and discharging, making it suitable for frequent backup scenarios, such as daily power outages in regions with unstable grids. The battery’s M6 threaded terminals ensure secure electrical connections, while its wide operating temperature range (-20°C to +50°C) guarantees performance in harsh industrial environments, from cold storage warehouses to high-temperature production floors.
With a 20-hour rate capacity of 7 Ah, the IBA 940143201 delivers consistent power for short to medium-duration outages, supporting critical loads like PLCs, HMIs, and safety systems until main power is restored. Its long shelf life (up to 3 years unloaded) reduces inventory turnover costs, while compliance with IEC 62133 and RoHS standards ensures global applicability and environmental sustainability.
Maintenance-free reliability: The ABB IBA 940143201 eliminates the need for regular water top-ups or electrolyte checks, reducing maintenance labor by 80% compared to traditional lead-acid batteries. A food processing plant used these batteries in their UPS systems, achieving five years of trouble-free operation with minimal oversight.
Vibration and shock resistance: Built with reinforced polypropylene casing, the battery withstands mechanical stress in industrial settings. A mining operation deployed the IBA 940143201 in underground control panels, where it endured continuous vibration from heavy machinery without compromising performance or safety.
Fast recharge capability: The battery supports rapid charging (up to 0.3C) without overheating, allowing systems to return to full backup capacity quickly after a discharge event. A pharmaceutical lab’s UPS system, equipped with IBA 940143201 batteries, recharged to 90% capacity within 4 hours, ensuring readiness for subsequent outages.
Environmental adaptability: The battery’s wide temperature range and non-spill design make it suitable for diverse applications. In a tropical region’s water treatment plant, the batteries operated reliably at 45°C, maintaining backup power for pumps and valves during monsoon-season power fluctuations.
Industrial UPS systems: The ABB IBA 940143201 provides backup power for PLCs and SCADA systems in manufacturing facilities. An automotive assembly line relied on these batteries to maintain control system operation during a 30-minute power outage, preventing costly production halts and ensuring compliance with just-in-time manufacturing schedules.
Critical infrastructure: In data centers and telecommunications hubs, the battery supports emergency lighting and access control systems. A regional data center used the IBA 940143201 in its fire alarm system, ensuring code-compliant emergency egress lighting during a prolonged grid failure.
Process control and safety systems: The battery powers safety-critical devices like emergency shutdown (ESD) systems in oil refineries. A chemical plant integrated the IBA 940143201 into its ESD panels, providing 60 minutes of backup power to close valves and vent systems during a simulated loss of main power.
Renewable energy storage: For off-grid solar or wind systems, the battery stores excess energy and provides backup during low-generation periods. A remote solar-powered weather station used the IBA 940143201 to maintain sensor operation through cloudy periods, ensuring uninterrupted data collection for climate research.
- ABB IBA 940143202: Higher-capacity variant (12 Ah) for longer backup durations in large UPS systems.
- ABB IBA 940143101: Compact 3.5 Ah version for space-constrained applications like small control panels.
- ABB IBP 500 Series: UPS systems designed to integrate with IBA batteries for seamless backup power solutions.
- ABB TB521: Terminal block accessories for secure battery wiring in control cabinets.
- ABB Charger Module 3BHB004180R0001: Compatible charger for optimized charging of IBA batteries in industrial setups.
- ABB Energy Storage System (ESS): Scalable ESS solutions that can incorporate IBA batteries for hybrid power systems.
Installation preparation: Ensure the installation area is dry, well-ventilated, and free of corrosive gases. Mount the IBA 940143201 in a vertical or horizontal position using the provided mounting brackets, leaving at least 20 mm clearance for airflow. Use insulated copper cables with M6 ring terminals to connect the battery to the UPS or control system, tightening terminals to 4–6 Nm to prevent loose connections. Avoid mixing old and new batteries in the same system to maintain consistent performance.
Maintenance suggestions: Inspect the battery monthly for signs of swelling, corrosion, or terminal looseness. Use a digital multimeter to check the battery voltage— a fully charged battery should read 12.6–12.8 V DC. If voltage drops below 12 V, recharge the battery using a compatible ABB charger. Replace batteries every 5–7 years or when capacity drops below 80% of nominal, as indicated by regular load testing. Dispose of old batteries through certified recycling channels to comply with environmental regulations.
ABB guarantees the IBA 940143201 to deliver nominal capacity and performance for 36 months from delivery. ABB’s global service network provides technical support for battery sizing, installation, and recycling, ensuring compliance with local regulations. For large-scale deployments, ABB offers Battery Health Monitoring Services, using remote diagnostics to track battery voltage, temperature, and cycle counts, enabling proactive replacement planning and minimizing unexpected downtime.
In the unlikely event of a manufacturing defect, ABB provides hassle-free replacement or repair. The IBA 940143201 undergoes rigorous testing for cycle life, temperature tolerance, and safety, reflecting ABB’s commitment to delivering industrial batteries that prioritize reliability, longevity, and environmental responsibility.
Shanxi Xinyeda International Trading Co., Ltd. is your trusted partner, we provide and other automation spare parts sales and technical support. Please visit our website www.xydcontrol.com or contact us and we will be happy to serve you.
Continue Searching
We're here when you need us
What happens next?
- 1. Email confirmation
You will get an email confirming that we have received your enquiry.
- 2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
- 3. Your quote
You will receive a comprehensive quote tailored to your specific needs.